X-ray Fluorescence Analyzer for Alloy Measurement

X-ray Fluorescence Analyzer for Alloy Measurement

 Solution Description
It can qualitative and quantitation analysis amongst various supplies other than factor C, also, the apparatus can overall performance nicely in Mg,Al,Si,S,P, and Mn which other device can not perform well. It primarily applied in the adhering to fields, these kinds of as steel,  fireproofing, non-ferrous industry, the high quality department, the plating thickness tests, ROSH inductor analysis and many others.
 Main Features

(one).Correct: Take a look at results can be close to take a look at wet chemical methods.

(two).Quick velocity: Testing large amounts elements in the sample only want couple of minutes.

(3).Non-loss: It can’t harm the physical and chemical houses in sample.

(four).Visually: Investigation final results are current directly in graph.

(five).CZPT: It can not pollute the setting.
Principal technical parameter

Analysis components Na-U,Largely are Al,Si,P,S,K,Ca,Ti,V,Fe,Ni,Mn,Pb,Zn,Cu,Sn,Sb,As and so on
investigation assortment 1 ppm-99.ninety nine%
measuring time All the contents investigation only in one-two minutes
analysis precision Regular deviation ≤0.08%
examination error Up to the typical requirments
radiation dosage <25  μ sv/h
setting temperature 15 ºC-35 ºC

Primary allocation

(one). Detection system

 Detector

 Type: electric powered refrigeration SDD detector

 Be window thickness: 50um

 The greatest resolution: 130eV

 CZPT reaction variety: 1keV-50keV

(2).X mild tube (for X ray spectrometer)

 Voltage: ~ 50kV

 Maximum recent: one.0mA

 Maximum energy: 50W

 Filament voltage: 2.0V

 Filament current: one.7A

 Ray out angle: twelve °

 Target: Mo

 Be window thickness: .5mm

(3).Substantial-voltage power source

 Input voltage: DC+24V ± ten%

 Input recent: 4.0A ( greatest )

 Output voltage: -5KV & 1mA

 Maximum electricity: 50W

 Voltage regulation rate: .01% ( from no load to complete load)

 Current adjustment charge: .01% ( from no load to complete load)

 Ripple element: .1% ( P-P worth)

 The steadiness of eight hours: .05%

(four). Vacuum pump

 Vacuum: vacuum test 20Pa restrict vacuum 2Pa

 (five). Optical integration design and style / program / vacuum cavity radiation protection

 X mild tube, detector, the composite filtertreatment system, CCD, positioning method, automatic collimator switching method processor optical route are integrated in a shut composition, make sure the balance of optical method with a shut optical route program as a vacuum cavity, via the loop and the maze efficiently by employing X ray greatest vitality at the same time to make sure the ray zero overflow.

 Packing & CZPT



 

X-ray Fluorescence Analyzer for Alloy Measurement