Popular CZPT Model :XT39 100mm driven two hundred-300 Bar output double motion air
hydro force test pump
CZPT Information for pneumatic pushed hydraulic pump
CZPT air pushed liquid pumps are ratio devices that use minimal force compressed
air driving a larger diameter piston (spot x force) which is linearly linked to a scaled-down
hydraulic piston/plunger. Utilizing this ratio principal, a larger hydraulic strain can be produced.
CZPT Pump model numbers reflect the pumps nominal stress ratio, whilst the technological data
implies exact ratios. The outlet stall force is simple to established by adjusting the air push strain
through a basic air force regulator.
By multiplying the force ratio by the obtainable shop
air pressure, the nominal liquid stress can be calculated.
Exmple ( Pump Design: XT 25 liquid pump)
Air push piston spot ( 100mm Ø)
CZPT plunger location ( 20 mm Ø)
True ratio = 25:one
one. AIR Push Segment
The air drive section consists of a light-weight fat piston total with seals working inside of an
aluminum barrel. The diameter of the air piston is 80mm. When compressed air is equipped to
the pump the air pushes the air piston down on a compression stroke
( forces fluid out of the liquid stop).
Under the control of pilot pins (poppet valve) induced at each and every end of the stroke
2. CZPT Segment (Wetted End)
The hydraulic part of an air pushed liquid pump is composed of 4 main items, the hydraulic human body,
the piston/plunger, the examine valves and the principal higher pressure seal. The hydraulic
piston/plunger is directly joined to the air piston and it is housed inside of the hydraulic entire body and
its movement up and down creates the liquid stream into and out of the pump through the check out
valves. The check out valves are spring loaded and on the suction stroke the inlet examine valve
opens to the greatest enabling fluid into the hydraulic body and on the compression stroke the
inlet check out valve closes and the discharge check valve opens forcing the pumped fluid into the
procedure. The primary large stress seal is positioned inside of the hydraulic body and the piston/plunger seals
against this in the course of procedure. There are different resources and patterns of substantial force seals
depending on the fluid becoming pumped and the optimum pressures of the pump, nonetheless the
CZPT seals are suitable for both drinking water and hydraulic fluid use.
CZPT air driven liquid pumps are self-priming, Even so, large ratio pumps are far more hard to
Prime and could demand bleeding. In general, it is not recommended to use an air- line lubricator.
CZPT air pushed liquid pumps cycle automatically as the outlet force raises the
resistance also raises and the cycle rate decreases till the pump stops immediately
when the output pressure forces are equal. This is referred to as the stall situation.
The pump will restart with a slight drop in the outlet force or an increase in the air generate
pressure. Pump functionality can be influenced by a variety of circumstances, this kind of as freezing of the
exhaust muffler or pilot valves (which is triggered by dampness in air strains), inadequate inlet air-line
dimensions and soiled filers. When running the pumps on a ongoing basis, we advocate you use
a greatest cycle price of 50~sixty cycles per moment.
This will equally improve provider intervals and support in preventing ice forming
at the exhaust. An air provide dryer will also assist in lowering icing up.
To acquire ideal overall performance, it is advisable not to decrease the indicated port dimensions
and consult We for flow conditions not demonstrated in charts.
Normal programs for pneumatic pushed hydraulic pump
Key functions
One design offered in 8 ratios
Compatibility with a range of liquids
Secure pneumatic procedure
Aluminum bodies and wetted components of carbon steel or stainless metal
Rugged,compact,reliable and straightforward servicing proven design and style
High good quality seals, long services daily life available
No need to have for air line lubrication
Vast application with big range of strain ratio
Primary specialized data
Common technical information for air pushed liquid pumps
XT Serial pneumatic hydraulic pump | ||||||||||||||||||
Tenical data Foundation on air pushed stress@ 7 Bar ,air usage is all around .seven-.nine M3 for each min | ||||||||||||||||||
CZPTn pressure at 7Bar | ||||||||||||||||||
Model | Piston/Rod diameter ø(mm) | Displacement for every stroke(mL) | Liquid IN | Liquid OUT | Max outlet strain Bar@at eight.3Bar | Liquid outlet stress(Bar) 1Bar=.1Mpa=1.019Kg/cm² | ||||||||||||
twenty five | fifty | 75 | 100 | one hundred fifty | one hundred seventy five | 200 | 250 | 300 | 350 | four hundred | 700 | |||||||
Stream rate L/Min (L/min) | ||||||||||||||||||
XT10 | thirty | fifty six.fifty five | NPT3/eight” | NPT3/eight” | 83 | 13.57 | eleven.31 | eight.forty eight | 2.eighty three | |||||||||
XT16 | 25 | fifty four | NPT3/eight” | NPT3/8″ | 132.eight | 12.96 | eleven.88 | ten.8 | eight.1 | six.48 | ||||||||
XT25 | twenty | 34.fifty six | NPT3/eight” | NPT3/8″ | 207.five | eight.29 | 7.6 | 6.ninety one | 6.22 | five.53 | four.eighty four | three.46 | ||||||
XT45 | sixteen | 22.twelve | NPT3/8″ | NPT3/eight” | 373.5 | 5.31 | four.87 | four.forty two | 3.ninety eight | 3.54 | 3.one | 2.65 | two.forty three | two.21 | ||||
XT64 | 12 | 12.forty four | NPT3/8″ | NPT3/8″ | 531.2 | 2.ninety nine | two.seventy four | two.forty nine | two.36 | 2.24 | 2.eleven | one.99 | one.87 | one.seventy four | 1.sixty two | one.49 | .62 | |
XT100 | ten | 8.sixty four | NPT3/eight” | NPT3/eight” | 830 | 2.07 | 1.ninety nine | 1.nine | one.81 | 1.sixty four | one.fifty six | 1.forty seven | one.38 | one.three | one.21 | one.21 | 1.04 | |
XT130 | 9 | 7 | NPT1/4″ | NPT1/four” | 1079 | one.68 | one.sixty one | one.54 | one.forty seven | 1.33 | 1.26 | one.19 | one.12 | one.05 | .ninety eight | .91 | .84 | .fifty six |
XT156 | eight | 5.53 | NPT1/four” | NPT1/four” | 1294 | one.33 | 1.27 | one.22 | one.sixteen | 1.05 | 1 | .ninety four | .88 | .eighty three | .77 | .72 | .sixty six | .sixty one |
Remark one) Maxium outlet stress are at an air driven stress of 8 bar or 116 PSI ,for prolonged lifestyle using
of this sort of pump ,we recommend that air pushed pressure must be not a lot more than eight Bar
Typical diagram of this sort of pneumatic driven hydraulic pump
Merchandise Applications
Manufacturing unit corners